Fieldbus Gateway & Board/ Ethernet Fieldbus Gateways/MGate 5217 Series

MGate 5217 Series

2-port Modbus RTU/ASCII/TCP-to-BACnet/IP gateways

MGate 5217 Series

Features and Benefits:

  • Supports Modbus RTU/ASCII/TCP master/client
  • Supports BACnet/IP slave/server
  •  Supports 600 points and 1200 points models
  • Supports COV for fast data communication
  • Supports virtual nodes designed to make each Modbus device as a separate BACnet/IP device
  • Configures Modbus commands quickly by editing an Excel spreadsheet
  • Embedded traffic and diagnostic information for easy troubleshooting
  • Built-in Ethernet cascading for easy wiring
  • Industrial design with -40 to 75°C operating temperature range
  • Serial port with 2 kV isolation protection
  • Dual AC/DC power supply
  • 5-year warranty
  • Security features based on IEC 62443

Certifications

  • moxa-ce-certification-logo-image.png | Moxamoxa-fcc-certification-logo-image.png | Moxamoxa-ul-listed-certification-logo-image.png | Moxa
  •  

DATASHEET DOWNLOAD    GET A QUOTE


Introduction

The MGate 5217I Series comprise 2-port BACnet gateways that can convert Modbus RTU/ACSII/TCP to BACnet/IP protocol. Depending on the size and the scale of the network, the gateways provide 600-point and 1200-point models. All models are rugged, DIN-rail mountable, operate in wide temperatures, and offer built-in 2kV isolation for serial signals.

Easy Configuration Via Web Console and Excel Spreadsheet

The MGate 5217I Series comes with an intuitive UI design to make configuration easy. With that, you can easily access protocol conversion modes and finish the configuration in a few steps instead of installing an additional engineering utility in your computer. Besides, the MGate can generate Modbus commands by importing an Excel spreadsheet, which makes it easy to edit Modbus commands.

Modbus and BACnet/IP Protocol Traffic Monitor and Diagnostics

The MGate 5217I gateways support Modbus and BACnet/IP Protocol Traffic Monitor and Diagnostics for easy troubleshooting, especially during the installation stage. Communication issues could be caused by incorrect software parameters, such as the wrong slave ID and register address, or an incorrect command configuration. With Diagnostics, you can check the communication status and view values at a glance. With Modbus/BACnet Protocol Traffic Monitor, you can check the captured data and easily identify the root cause.

Security Features Based on IEC 62443

Using network devices that are IEC 62443-4-2 compliant and equipped with basic security capabilities is an effective precautionary measure to ward off cyberattacks. The MGate 5217I Series is capable of several basic security capabilities, including password cracking defense, sniffer and data breach prevention, whitelisting, and the account management.